Speci cations
DIN-rail Controller Module
Input Power
24vdc +/- 20% (7 watts max)
Input Fuse
1 amp fast blow (pico size)
Relay Outputs
K1, K2 Safety N.O.
8A@250v resistive
(4A@120vac recommended max)
130V surge suppression devices are installed
inside the Controller Module. This limits the
recommended maximum voltage to 120VAC.
Please consult factory if you need to switch higher
voltages.
K3 Aux N.O. & N.C.
8A@250v resistive
(4A@120vac recommended max)
K4 Fault N.O.
8A@250v resistive
(4A@120vac recommended max)
Indicators
External:
OK/CLEAR Green LED
BLOCK/FAULT Red LED
BLANKING ACTIVE Yellow LED
BLOCKED Red LED
Internal:
D1 +5v Yellow D3 +12v Red
D14 K2 relay Green D13 K1 relay Green
D16 K3 relay Green D15 K4 relay Green
D19 +5v Yellow D18 -5v Green
Construction
Controller Module: DIN-rail mountable
polycarbonate housing providing IP40 protection,
UL94V-1.
Pylons: Painted aluminum extrusion with
polycarbonate IR lens and Viton seals providing
NEMA 12, 13 protection. An optional polycarbonate
tube provides NEMA 4 protection.
Cables: Shielded PVC 22 AWG stranded.
Standard length: 20’ Emitter; 8’ Receiver
Temperature Range
0 to 50°C (up to 95% humidity, non-condensing)
Dimensions
Controller Module: 5.87” length X 2.95” width X
4.33” height DIN-rail mount is 35.5mm (1.4”) wide.
Pylons: 1.45” square.
Beam Spacing
.5” (12.7mm) standard
1” [25.4mm] (optional). The Floating Blank option
changes the effective beam spacing.
Minimum Object Sensitivity:
.5” (12.7mm) beam spacing is .55” (14mm)
1” (25.4mm) beam spacing is 1.18” (30mm)
Response Time < 30 mSec total
Scanning Frequency 5.9 KHz
Shock Tested to withstand high vibration applications
Self-Checking every 20 milliseconds
Scanning Distance All units are supplied standard
with a 20’ scanning capability. Extended range units
are available and must be speci ed (35’ maximum).
Maximum Operating Distance Stated as last two
digits in model number