D - 2
Appendix “D”
USB Diagnostic Codes
Model MG or DR USB Diagnostic Codes: Master Controls USB port Cont.
Note: You must install the Silabs CP210x USB driver on your windows PC. Check your Device
Manager for Silabs COM port#. You read the port at 230400 Baud 8N1
Fault Codes: in HEX code
Mute-out switch fault ", 01
Open LED in emitter pylon ", 02
Short LED in emitter pylon ", 03
Emitter length fault ", 04
Receiver length fault ", 05
External contact welded or wire cut ", 06
External contact short ", 07
Internal relay is stuck on ", 08
Internal relay is not energizing ", 09
No data line detected ", 0A
No clock line detected ", 0B
No emitter line detected ", 0C
External infrared source detected ", 0D
Internal relay bad/missing ", 0E
Serial data corrupted ", 12
Serial data transfer incomplete ", 13
Emitter on at wrong time ", 15
Receiver oscillating ", 16
NO MORE FAULT CODES ", 17
Not Synced up with Slave ", 1F
Old FAULTS from Memory: ", 25
" ------------------ " 27
Proper power up example: SEMF0P <CR> 10 lines of EEPROM memory <CR> GA0024m (for a 24 beam length guard)
Blocked Beam pattern display:
If you transmit the ASCII character ‘B’ via the USB port, the Microguard will return a string of ASCII charac-
ter 1’s and 0’s based on the beam blockage.
The start of the string represents the beam closest to the cable end, and the end of the string is represented
by the ASCII character ‘@’
0 = clear beam
1 = blocked beam
Example for an MG-04-0F-20 model (which has a total of 8 beams):
Send ‘B’, then you Receive 01100000@
This indicates 2 blocked beams (2nd and 3rd beams from the cable end)